top of page

Super Duty Power Perfect Box Technical Specifications

Gen III SATIC PowerPerfect Circuit Module Models ES1PN + ES1PP Product Features and Benefits
Features
Benefits

• Interference (EMI/RF) noise reduction 0-50 dB

• Voltage modulation

• Three-way electrical protection

• Self-healing metalized harmonic rectifiers

• Robust tri-circuit integrated surge protection

• Corrects current phase quality

• Low electromagnet field radiation (EMF/EMR)

• Low total harmonic distortion (THD)

• All three electrical pathway production

• Long life

• Built-in surge and EMP protection

• Power factor correction

GEN III SATIC POWERPERFECT SPECIFICATIONS
 

Circuit Configuration 1: 120/240 V split phase power conditioner

Max AC Voltage Component Rating:  300 Volts

Power-loss Rating: <0.5 W per 1000 VAr

Input Frequency: 50/60 Hz

Wire Rating:  600 V THNN, 15 AWG terminated to 15 A DP

Current Requirements @ 120/208 Volts:       3.52 A (L1 & L2), 0.34 A (N)

Enclosure: 14" x 7.25" x 4" NEMA 4X indoor/outdoor

Operating Temperature:  -55°C to +90°C

Operating Humidity:  5% to 95%, noncondensing

Operating Altitude:  Up to 16,000 ft (5000m)

Seismic Withstand Capability: IBC 2021, CBC 2021, UBC Zone 4

Harmonic Rectifier Circuit DETAILS

Total Unit Reactive Power @ 300 V (L1-L2 + L1-N + L2-N) + 3* (L1-L2)      120 μF --> 1.5 kVAr

Per Circuit Reactive Power @ 300 V (L1-L2 & L1-N & L2-N) + 3* (L1-L2)     20 μF L-N --> 0.3 kVAr. 60μF L-L --> 1.2 kVAr

Reactive Bank Composition:    36 PFC Modules ES1PN + 36 PFC modules ES1PPP

Harmonic Dissipations - PFC Module Specs.

Tangent of Loss Angle; C > 1 μF at 1 kHz:                  <=30 * 10

Rated Voltage Pulse Slope (dV/dt)                              150 V/μs

RC Between Leads:                                                     >5000 s

Withstanding(DC) Voltage (Cut-off Current 10 mA):    1850 V

EMI/RMI Filtering Attenuation:                                      Up to 50 dB form 10 kHz to 100 MHz

Protection Modes:                                                        (L1-L2 & L1-N & L2-N) + 3*(L1-L2)

-4

Surge and emp Suppression

RMS

RMS

DC

A/C Voltage Max                                             (Continuous)     150v (L1-N, L2-N) 250v (L1-L2) V

D/C Voltage Max                                                                       424v V

A/C Voltage Max                                         (Max Clamping)     650v V

Current Max Peak                                            (Peak Surge)     6500A A

Transient Dissipation Potential Each Circuit (Surge Energy)    1,300 per pathway * 6 = 7,800 J / μs

Protection Modes                      (Dual Tri-Circuit Integration)    L1-L2, L1-N, L2-N@150v + 3*(L1-L2)

Description/Code
  • Made in USA

  • UL / CSA - E337361 - Open Energy Management Equipment 3ZJ9

  • FCC - Approved (UL Tested for Compliance)

  • CE - Low Voltage Directive 2006/95/EC

  • CE - Electromagnetic Compatibility (EMC) 2004/108/EC

  • RoHS - Lead Free - Restriction of Hazardous Substances

Super Duty Power Perfect Box Accreditations
Screen Shot 2021-01-08 at 12.50.51 PM.pn